PicoScope 3000 Series PC Oscilloscopes

The PicoScope 3000 series
oscilloscopes are the latest
offerings from the market
leader in PC oscilloscopes
combining high bandwidths
with large record memories.
Using the latest advances
in low power electronics,
the oscilloscopes draw
their power from the USB
port of any modern PC,
eliminating the need for
mains power.
• High performance: 10GS/s sampling rate
& 200MHz bandwidth
• 1MB buffer memory
• Advanced display & trigger modes
• Compact & portable
• Supplied with PicoScope
(oscilloscope/spectrum analyser)
& PicoLog (data acquisition) software.
PicoScope 3204 3205 3206
Bandwidth 50MHz 100MHz 200MHz
Sampling rate (repetitive)

2.5GS/s

5GS/s

10GS/s

Sampling rate (single shot) 50MS/s 100MS/s 200MS/s
Channels 2+Ext trigger/Sig gen 2+Ext trigger/Sig gen 2+Ext trigger/Sig gen
Oscilloscope timebases 5ns/div to 50s/div 2ns/div to 50s/div 1ns/div to 50s/div
Timebase accuracy 50ppm 50ppm 50ppm
Spectrum ranges 0 to 25MHz 0 to 50MHz 0 to 100MHz
Record length 256K 512K 1MB
Resolution accuracy
8 bits / 3%
Ranges
10mV to 2V/div
PC Connection/Power supply
USB2.0 (USB1.1 compatible)
Price $ $ $

PicoScope Oscilloscopes and Spectrum Analyzers

  • Compact and portable units
  • Uses your PC monitor to provide a large and detailed colour display
  • Signal storage is limited only by the PC's storage capability
  • Captured waveforms and instrument settings can easily be shared with others
  • New functionality through free software upgrades
  • Can be used with desktop or laptop PCs
  • Hardware and software in one package: no compatibility problems or complex setup procedures
  • Units are also supplied with PicoLog data logging software , which transforms your PC into a high speed data logger
  • 2 or 4 Channels
  • 12 bit resolution
  • Accurate to within 1%
  • 72 dB dynamic range
  • High-speed USB 2.0 interface
 
PICOSCOPE3224
PICOSCOPE3424
Bandwidth
10 MHz
Sampling rate (single shot) 20 MS/s (1 channel)
10 MS/s (2 channels)
20 MS/s (1 channel)
10 MS/s (2 channels)
5 MS/s (3 or 4 channels)
Channels
2 x BNC
4 x BNC
Oscilloscope timebases
500 ns/div to 20 s/div
Timebase accuracy
100 ppm
Spectrum ranges
DC to 10 MHz
Dynamic range
72dB
Trigger modes
Free Run, Auto, Repeat, Single and Save To Disk On Trigger
Pre/post trigger
-100% to +100%
Buffer size
512 kS
Resolution
12 bits
Accuracy
±1%
Voltage ranges
±20 mV to 20 V in 10 ranges
Overload protection
±100 V
Input impedance
1 MO
PC connection
USB 2.0 (USB 1.1 compatible) - cable supplied
Power supply
From USB port
Dimensions
140 x 190 x 45 mm  (5.51 x 7.48 x 1.77 in)
Environmental
+20 °C to +30 °C for quoted accuracy, 0 °C to +70 °C overall.
20 to 90% RH
Supplied software PicoScope (oscilloscope, spectrum analyser, meter)
PicoLog (data logger)
Drivers and examples (C, Delphi and Visual Basic, Labview, Agilent VEE6.1 and Excel)
PC requirements Processor : Pentium class processor or equivalent
Memory : 32 MB minimum
Disk space : 10 MB minimum
Operating system : Microsoft Windows 98SE, ME, 2000, XP or later
Ports : USB 1.1 compliant port minimum. USB 2.0 compliant port recommended. Must be connected direct to the port or a powered USB hub
Price $

PC Oscilloscopes for Automotive Diagnostics

  • High resolution and precision
  • Large sample memory allows waveform detail to be expanded
  • Unlimited storage of waveforms and settings
  • Advanced trigger modes capture intermittent faults
  • Free software updates and technical support
  • 2 or 4 channels
  • No power supply required
  • USB 2.0 (USB 1.1 compatible) connection for fast screen updates
  • 512,000 sample memory
  • 50 V  maximum input
  • Protected against overloads and short circuits
  • Includes PicoScope Automotive software
 
PICOSCOPE3223
PICOSCOPE3423
Resolution
12 bits
Channels 2 x BNC 4 x BNC
Voltage ranges
±20 mV to 50 V in 11 ranges
Overload protection
±100 V
Input impedance
1 MO
Sampling rate (single shot) 20 MS/s (1 channel)
10 MS/s (2 channels)
20 MS/s (1 channel)
10 MS/s (2 channels)
5 MS/s (3 or 4 channels)
Accuracy
±1%
Bandwidth
10 MHz
Buffer size
512 kS
Dimensions
140 x 190 x 45 mm  (5.51 x 7.48 x 1.77 in)
PC connection
USB 2.0 (USB 1.1 compatible) - cable supplied
Power supply
From USB port
Environmental
+20 °C to +30 °C for quoted accuracy, 0 °C to +70 °C overall.
20 to 90% RH
Supplied software PicoScope Automotive for Windows 98SE/ME/2000/XP
PC requirements Processor : Pentium class processor or equivalent
Memory : 32 MB minimum
Disk space : 10 MB minimum
Operating system : Microsoft Windows 98SE, ME, 2000, XP or later
Ports : USB 1.1 compliant port minimum. USB 2.0 compliant port recommended. Must be connected direct to the port or a powered USB hub
Price $